Green Tips for Data Centers [Pehme köide]

  • Formaat: Paperback / softback, 93 pages, illustrations
  • Sari: Ashrae Datacom
  • Ilmumisaeg: 07-Apr-2011
  • Kirjastus: American Society of Heating Refrigerating and Air-Conditioning Engineers
  • ISBN-10: 193374295X
  • ISBN-13: 9781933742953
Teised raamatud teemal:
  • Pehme köide
  • Hind: 68,86 €*
  • * saadame teile pakkumise kasutatud raamatule, mille hind võib erineda kodulehel olevast hinnast
  • See raamat on trükist otsas, kuid me saadame teile pakkumise kasutatud raamatule.
  • Kogus:
  • Lisa ostukorvi
  • Tasuta tarne
  • Lisa soovinimekirja
  • Formaat: Paperback / softback, 93 pages, illustrations
  • Sari: Ashrae Datacom
  • Ilmumisaeg: 07-Apr-2011
  • Kirjastus: American Society of Heating Refrigerating and Air-Conditioning Engineers
  • ISBN-10: 193374295X
  • ISBN-13: 9781933742953
Teised raamatud teemal:
"Gives data center owners and operators a clear understanding of the energy-saving opportunities that exist for both the data center facility and the IT equipment and covers the mechanical and electrical systems of the building as well as the most promising technologies. Can be used for conducting preliminary energy assessment"--

A typical data processing and telecommunications facility uses about 300 times more electricity per year than an entire office building, and as the price of energy and environmental concerns both continue to rise, owners and operators of such facilities are seeking ways to cut back consumption without jeopardizing the reliability of the data. Engineers from the Society offer some advice in the areas of energy management, environmental conditions, air management, the cooling plant information technology power distribution, lighting, and information technology equipment. There is no index. Annotation ©2011 Book News, Inc., Portland, OR (booknews.com)
Acknowledgments vii
Preface ix
1 Energy Management
Green Tip 1a Install Monitoring Equipment to Measure Efficiency and Performance
1(5)
Green Tip 1b Rightsize the Cooling and Power Infrastructures
6(5)
2 Environmental Conditions
Green Tip 2a Optimize Supply Air Temperatures
11(3)
Green Tip 2b Improve CRAC Unit Controls
14(3)
Green Tip 2c Optimize Humidity Control
17(4)
3 Air Management
Green Tip 3a Improve Return Air Management
21(4)
Green Tip 3b Separate Hot and Cold Airstreams
25(4)
Green Tip 3c Improve Underfloor Pressure Management
29(3)
Green Tip 3d Optimize IT Equipment Cabinet Airflow
32(3)
Green Tip 3e Improve CRAC/CRAH Unit Efficiency
35(6)
4 Cooling Plant
Green Tip 4a Install Variable-Speed Drives
41(2)
Green Tip 4b Cooling Plant Strategies
43(5)
Green Tip 4c Increase Water Efficiency
48(2)
Green Tip 4d Optimize Pumping Control
50(4)
Green Tip 4e Use of Waste Heat
54(3)
Green Tip 4f Optimize Chilled-Water and Condenser-Water Supply Temperatures
57(3)
Green Tip 4g Improve Pumping Efficiency
60(2)
Green Tip 4h Direct-Expansion (DX) vs. Chilled-Water Systems
62(3)
5 IT Power Distribution
Green Tip 5a Improve UPS Efficiency
65(2)
Green Tip 5b Improve Transformer Efficiencies
67(2)
6 Lighting
Green Tip 6a Improve Lighting Efficiency
69(4)
7 IT Equipment
Green Tip 7a Implement Server Virtualization
73(2)
Green Tip 7b Optimize Data Storage
75(2)
Green Tip 7c Enable Power Management Features
77(1)
Green Tip 7d Specify High-Efficiency Power Supplies
78(2)
Green Tip 7e Rightsizing the IT Installation
80(3)
Abbreviations and Acronyms 83(2)
Glossary 85(6)
References 91