Muutke küpsiste eelistusi

Implantable Defibrillator Therapy: A Clinical Guide 2002 ed. [Kõva köide]

  • Formaat: Hardback, 410 pages, kõrgus x laius: 235x155 mm, kaal: 1720 g, X, 410 p., 1 Hardback
  • Sari: Developments in Cardiovascular Medicine 244
  • Ilmumisaeg: 31-Aug-2002
  • Kirjastus: Springer-Verlag New York Inc.
  • ISBN-10: 1402071434
  • ISBN-13: 9781402071430
Teised raamatud teemal:
  • Kõva köide
  • Hind: 141,35 €*
  • * hind on lõplik, st. muud allahindlused enam ei rakendu
  • Tavahind: 166,29 €
  • Säästad 15%
  • Raamatu kohalejõudmiseks kirjastusest kulub orienteeruvalt 2-4 nädalat
  • Kogus:
  • Lisa ostukorvi
  • Tasuta tarne
  • Tellimisaeg 2-4 nädalat
  • Lisa soovinimekirja
  • Formaat: Hardback, 410 pages, kõrgus x laius: 235x155 mm, kaal: 1720 g, X, 410 p., 1 Hardback
  • Sari: Developments in Cardiovascular Medicine 244
  • Ilmumisaeg: 31-Aug-2002
  • Kirjastus: Springer-Verlag New York Inc.
  • ISBN-10: 1402071434
  • ISBN-13: 9781402071430
Teised raamatud teemal:
Doubling as a textbook and reference, this volume contains 15 chapters covering indication, instrumentation, implantation, follow-up, and complications. Black-and-white illustrations provide visual representations of the relevant anatomy. Contributors include doctors and scientists from the United States and Germany. Annotation (c) Book News, Inc., Portland, OR (booknews.com)

Implantable defibrillators as originally conceived by Michel Mirowski were limited to the detection and automatic termination of ventricular fibrillation. In the original "AID" device, the detection algoritlun sought to distinguish sinus rhytlun from ventricular fibrillation by identifying the "more sinusoidal waveform of ventricular fibrillation. " The therapeutic intervention was elicited only once deadly polymorphic rhythms had developed. It was rapidly learned, however, that ventricular fibrillation is usually preceded by ventricular tachycardia. Mirowski recognized the pivotal importance of developing algoritllms based on heart rate. Ventricular tachycardia detection allowed the successful development of interventions for the termination of ventricular tachyarrhythmias before they degenerated into ventricular fibrillation. Current device therapy no longer confines itself to tlle termination of chaotic rhythms but seeks to prevent them. Diagnostic algorithms moved upward along the chain of events leading to catastrophic rhytlulls. Rate smoothing algorithms were developed to prevent postextrasystolic pauses from triggering ventricular and atrial tachyarrhytlmlias. Beyond the renaissance of ectopy-centered strategies, long-term prevention received increasing attention. Multisite pacing therapies provided by "Arrhythmia Management Devices" were designed to reduce the "arrhytlunia burden" and optimize the synergy of cardiac contraction and relaxation. Clinical evidence now suggests that atrial fibrillation prevention by pacing is feasible and tllat biventricular pacing may be of benefit in selected patients with heart failure. However, these applications of device therapy that generally require ventricular defibrillation backup remain investigational and were not considered in this book.

Muu info

Springer Book Archives
1. Indication for ICD Therapy.-
2. Overview of Instrumentation.-
3. Defibrillator Leads.-
4. Atrial Defibrillators.-
5. Implantation.-
6. Device Testing and Programming at Implantation.-
7. Testing at Discharge.-
8. Postoperative Follow-up and Complications.-
9. Long-Term Follow-up.-
10. Adjunctive Antiarrhythmic Drug Therapy.-
11. Lead System Dysfunction, Diagnosis, and Therapy.-
12. Device Proarrhythmia.-
13. Electromagnetic Interference (EMI).-
14. Anxiety and Depression.-
15. ICD Trial Appendix.