Muutke küpsiste eelistusi

Mastering the Techniques of IOL Power Calculations, Second Edition 2nd edition [Kõva köide]

  • Formaat: Hardback, 400 pages, kõrgus x laius x paksus: 279x221x26 mm, kaal: 1745 g, 0 Illustrations
  • Ilmumisaeg: 16-Sep-2009
  • Kirjastus: McGraw-Hill Medical
  • ISBN-10: 0071634363
  • ISBN-13: 9780071634366
Teised raamatud teemal:
  • Kõva köide
  • Hind: 136,89 €*
  • * saadame teile pakkumise kasutatud raamatule, mille hind võib erineda kodulehel olevast hinnast
  • See raamat on trükist otsas, kuid me saadame teile pakkumise kasutatud raamatule.
  • Kogus:
  • Lisa ostukorvi
  • Tasuta tarne
  • Lisa soovinimekirja
  • Formaat: Hardback, 400 pages, kõrgus x laius x paksus: 279x221x26 mm, kaal: 1745 g, 0 Illustrations
  • Ilmumisaeg: 16-Sep-2009
  • Kirjastus: McGraw-Hill Medical
  • ISBN-10: 0071634363
  • ISBN-13: 9780071634366
Teised raamatud teemal:
Publisher's Note: Products purchased from Third Party sellers are not guaranteed by the publisher for quality, authenticity, or access to any online entitlements included with the product.

Presents all aspects of IOL power calculations by international masters of the field.

In the past, patients quietly accepted needing an eyeglass prescription after cataract surgery. That is no longer true. This textbook explains just why a more complex evaluation of the eye is needed, and will describe the state of the art in the technology used to ensure the best possible results today.

IOL power calculation is a complex and important subject. A number of new formulas have come up for cataract and refractive surgeons which deliver good outcomes and provide another avenue to validate IOL selections. This international book of IOL power calculations covers all aspects of calculations from normal cornea to after refractive surgery, in Phaco/Microphaco, on irregular corneal surgace, in phakic IOLs, in corneal scarring and astigmatism, and in pediatric cataract surgery.
Section 1: Preliminary Considerations and Various IOL Power Calculation Formulas and Basics
Schematic Eye
3(2)
Athiya Agarwal
Amar Agarwal
Ashok Garg
A-scan Biometry
5(5)
Sunita Agarwal
Amar Agarwal
Ashok Garg
Corneal Topography
10(11)
Athiya Agarwal
Sunita Agarwal
Amar Agarwal
Nilesh Kanjani
Optical Corneal Tomography
21(3)
Sandra Franco
Jose B Almeida
Manuel Parafita
Optical Biometry with IOL Master (Partial Coherence Interferometry)
24(2)
Ashok Garg
Anterior Chamber Depth in IOL Power Estimation
26(2)
Aravind R Reddy
How to Calculate the Constant A
28(3)
Sonja Hairer
Tom Conze
Jerome Bovet
Axial Length Dependence of IOL Constants
31(5)
Wolfgang Haigis
IOL Calculations: When, How and Which?
36(10)
Kumar J Doctor
Nita Shanbhag
Sumita Karandikar
Pooja Deshmukkh
How to Measure a Correct Central Keratometric Reading for IOL Power Calculation after LASIK Surgery?
46(5)
Lung-Kun Yeh
I-Jong Wang
An Update on IOL Power Calculation Formulas
51(11)
JT Lin
Ashok Garg
The New IOL Formulas based on Gaussian Optics
62(8)
JT Lin
Classical vs Modern Formulas for Estimated Lens Position (ELP)
70(5)
JT Lin
IOL Power Calculations
75(17)
Kenneth J Hoffer
The Theoretical Summary of IOL Formulas
92(9)
JT Lin
Error Analysis of IOL Power Calculations
101(5)
JT Lin
The Basics of Accommodating IOLs
106(8)
JT Lin
IOL Calculation in Long and Short Eyes
114(7)
Wolfgang Haigis
Customization of IOL Formulas
121(6)
B Vineeth Kumar
Section 2: IOL Power Calculations in Cataract Surgery
Intraocular Lens Power Selection for Children
127(9)
Rupal H Trivedi
M Edward Wilson Jr
Age Dependent IOL Power Calculations for Pediatric Patients
136(6)
JT Lin
History & Method of Intraocular Lens Power Calculation for Cataract Extraction Surgery after Corneal Refractive Surgery
142(4)
Alberto Artola Roig
Jorge L Alio Y Sanz
Intraocular Lens Power Calculations in Phaco and Microphaco
146(7)
Ashok Garg
Arif Adenwala
Intraocular Lens Power Calculations for High Myopia
153(6)
Renyuan Chu
Jinhui Dai
Accuracy of Intraocular Lens Power Calculation in Bimanual Microphacoemulsification
159(5)
Gian Maria Cavallini
Luca Campi
Giovanni Neri
Clinical Outcomes of Cataract Surgery after Previous Refractive Surgery
164(11)
Frank J Goes
Section 3: IOL Power Calculations in Refractive Surgery (Corneal and Lenticular Refractive Surgery)
IOL Power Calculations: A Topographic Method
175(5)
Frederic Hehn
IOL Power Calculation in Post-hyperopic PresbyLASIK Cataract: Preliminary Results
180(4)
Roberto Pinelli
Comparison of Methods for IOL Power Calculation after Incisional and Photoablative Refractive Surgery
184(21)
Antonio Colossi
Massimo Camellin
IOL Power Calculations after Corneal Refractive Surgery
205(8)
Srinivas K Rao
Arthur Cheng
Dennis SC Lam
The Latkany Regression Formula for Intraocular Lens Calculations after Myopic Refractive Surgery
213(5)
Evelyn Icasiano
Robert Latkany
The Latkany Regression Formula for Intraocular Lens Calculations after Hyperopic Refractive Surgery
218(3)
Evelyn Icasiano
Robert Latkany
Which IOL Formula to Use after Refractive Surgery
221(4)
Sonja Hairer
Tom Conze
Jerome Bovet
Intraocular Lens Power Calculation after Advanced Surface Ablations (ASA)
225(6)
Tsiklis NS
Kymionis GD
Portaliou DM
Pallikaris IG
The Mathematics of LASIK
231(7)
JT Lin
Preoperative Evaluation of the Anterior Chamber for Phakic IOLs with the AC OCT
238(6)
Georges Baikoff
Biometry for Refractive Lens Surgery
244(8)
Mark Packer
I Howard Fine
Richard S Hoffman
IOL Power Calculations in Phakic IOLs
252(2)
Dimitrii Dementiev
Kukrenkov Vetchiaslav
Raytracing Analysis of Accommodating IOL
254(5)
Yoshiaki Nawa
Analysis of Dual-optics Accommodating IOLs
259(6)
JT Lin
Aspherical IOL Analysis
265(12)
JT Lin
Section 4: Miscellaneous (Recent Advances and IOL Power Calculations in Difficult Situations)
Determining Corneal Power for Intraocular Lens Calculations in Patients with Corneal Scarring and Irregular Astigmatism
277(4)
Mujtaba A Qazi
Irwin Y Cua
Jay S Pepose
IOL Calculation in Hyperopes
281(4)
Wolfgang Haigis
Frank J Goes
Consistent IOL Calculation in Normal and Odd Eyes with the Raytracing Program OKULIX
285(7)
Paul Rolf Preussner
A-scan in Difficult Situations
292(13)
Anand A Shroff
Management of Refractive Surprises after Cataract Surgery
305(9)
Armando Capote
Eneida de la C Perez
Marcelino Rio
Intraocular Lens Power Calculation in the High Myopic Eye
314(4)
Fengju Zhang
Yan Wang
Calculation of Intraocular Lens Power in Cataract with Silicone Oil Eyes
318(2)
Fengju Zhang
Yan Wang
Intraoperative IOL Power Calculation
320(7)
Arturo Perez-Arteaga
ZEMAX Raytracing Method for Accommodative IOL
327(4)
JT Lin
Minshan Jiang
Problems of IOL Power Calculation in Pediatric Cataract Surgery
331(6)
Marek E Prost
Intraocular Lens Calculation after Prior Refractive Surgery
337(8)
Kenneth J Hoffer
Cataract Surgery: Calculating the IOL Power in Case of Anisometropia
345(11)
Laure Gobin
Jos J Rozema
Marie-Jose Tassignon
Review of IOL Power Calculation: A Theoretical Analysis of Proposed Formulas
356(12)
Laure Gobin
Jos J Rozema
Marie Jose Tassignon
IOL Power Calculation for Cornea Triple and Penetrating Keratoplasty with IOL Exchange
368(3)
Ashok Sharma
IOL Power Calculations in Eyes with Irregular Corneas
371(4)
Barun K Nayak
Sunil Moreker
Index 375
Ashok Garg, MS, PhD, is Chairman and Medical Director of the Garg Eye Institute & Research Centre, Hisar, India. J.T. Lin, PhD, is currently the Director of New Vision, Inc. in Rochester, NY. He designed the world most compact Excimer system for PRK/LASIK (in 1993), the world's first tunable IR-laser from OPO/KTP (1990) and the first diode-pumped green laser from NYAB (in 1989). Lin holds over 30 international patents in laser systems and surgical methods. Robert Latkany, MD, is the founder and director of the Dry Eye Clinic at the New York Eye and Ear Infirmary as well as the Dry Eye Center of New York, the first center in the area devoted to dry eye disorders. Jerome Bovet, MD, practices at Clinique de l'Oeil in Geneva, Switzerland. Wolfgang Haigis, PhD, is Assistant Professor of ophthalmic Biometry, Faculty of Medicine, University of Wuerzburg, Germany.