Muutke küpsiste eelistusi

On-Site Guide (BS 7671:2008plusA3:2015) 6th edition [Spiraalköide]

  • Formaat: Spiral bound, 208 pages, kõrgus x laius: 210x148 mm
  • Sari: Electrical Regulations
  • Ilmumisaeg: 18-Feb-2015
  • Kirjastus: Institution of Engineering and Technology
  • ISBN-10: 184919887X
  • ISBN-13: 9781849198875
Teised raamatud teemal:
  • Formaat: Spiral bound, 208 pages, kõrgus x laius: 210x148 mm
  • Sari: Electrical Regulations
  • Ilmumisaeg: 18-Feb-2015
  • Kirjastus: Institution of Engineering and Technology
  • ISBN-10: 184919887X
  • ISBN-13: 9781849198875
Teised raamatud teemal:
Vital changes have been made in Amendment 3 regarding safety for contractors and consumers. This essential quick-reference guide to BS 7671 has been updated to the changes in Amendment 3 to BS 7671:2008.



The On-Site Guide is designed to be taken on-site for easy referencing and provides simple guidance on the application of BS 7671.



All updates in Amendment 3 will be included in the On-Site Guide, which include, but are not limited to:







Consumer units (to come into effect January 2016) Wiring in escape routes Changes to earth fault loop impedances for all protective devices Circuit-breakers used as functional switches Overvoltages EMC & compatibility Changes to definitions throughout the Regulations



Amendment 3 published on 5 January 2015 and comes into effect on 1 July 2015. All new installations from this point must comply with Amendment 3 to BS 7671:2008.
  • Section 1: Introduction
  • Section 2: The electrical supply
  • Section 3: Protection
  • Section 4: Earthing and bonding
  • Section 5: Isolation and switching
  • Section 6: Labelling
  • Section 7: Final circuits
  • Section 8: Locations containing a bath or shower
  • Section 9: Inspection and testing
  • Section 10: Guidance on initial testing of installations
  • Section 11: Operation of RCDs
  • Appendix A: Maximum demand and diversity
  • Appendix B: Maximum permissible measured earth fault loop impedance
  • Appendix C: Selection of types of cable for particular uses and external influences
  • Appendix D: Methods of support for cables, conductors and wiring systems
  • Appendix E: Cable capacities of conduit and trunking
  • Appendix F: Current-carrying capacities and voltage drop for copper conductors
  • Appendix G: Certification and reporting
  • Appendix H: Standard circuit arrangements for household and similar installations
  • Appendix I: Resistance of copper and aluminium conductors
  • Appendix J: Selection of devices for isolation and switching
  • Appendix K: Identification of conductors