Thermal Guidelines for Data Processing Environments [Kõva köide]

  • Formaat: Hardback, 46 pages, Illustrations
  • Ilmumisaeg: 01-Jan-2004
  • Kirjastus: Ashrae
  • ISBN-10: 1931862435
  • ISBN-13: 9781931862431
Teised raamatud teemal:
  • Kõva köide
  • Hind: 56,87 €*
  • * saadame teile pakkumise kasutatud raamatule, mille hind võib erineda kodulehel olevast hinnast
  • See raamat on trükist otsas, kuid me saadame teile pakkumise kasutatud raamatule.
  • Kogus:
  • Lisa ostukorvi
  • Tasuta tarne
  • Lisa soovinimekirja
  • Formaat: Hardback, 46 pages, Illustrations
  • Ilmumisaeg: 01-Jan-2004
  • Kirjastus: Ashrae
  • ISBN-10: 1931862435
  • ISBN-13: 9781931862431
Teised raamatud teemal:
This guide provides a framework for improved alignment between IT equipment hardware manufacturers (including manufacturers of computers, servers, and storage products), data center designers, and facility operators and managers. The guide covers four primary areas: equipment operating environment specifications, facility temperature and humidity measurement, equipment placement and airflow patterns (a hot- aisle/cold-aisle layout is recommended), and equipment manufacturers' heat load and airflow requirements reporting. Guidelines for facility operation personnel show how to lay out data centers for optimum reliability. Guidelines for manufacturers give advice on providing the airflow path for their equipment. Guidance on evaluating and testing the operational health of the data center and on reporting the environmental characteristics of a computer system is also given. Appendices contain psychometric charts and temperature and altitude charts. The first page of the book features a plastic cover holding a removable list of equipment thermal guidelines for data processing environments. Annotation ©2009 Book News, Inc., Portland, OR (booknews.com)
ACKNOWLEDGMENTS ix
CHAPTER 1 INTRODUCTION 1(8)
1.1 Document Flow
2(1)
1.2 Primary Users for This Document
3(1)
1.3 Timeline and Compliance
4(1)
1.4 Definitions
4(5)
CHAPTER 2-EQUIPMENT ENVIRONMENT SPECIFICATIONS 9(6)
2.1 Environmental Conditions
9(2)
2.2 Environmental Class Definitions
11(1)
2.3 Equipment Environmental Specifications
12(1)
2.4 Altitude Rating
12(2)
2.5 Acoustical Noise Emissions
14(1)
CHAPTER 3 FACILITY TEMPERATURE AND HUMIDITY MEASUREMENT 15(8)
3.1 Facility Health and Audit Tests
15(3)
3.1.1 Aisle Measurement Locations
15(3)
3.1.2 HVAC Operational Status
18(1)
3.1.3 Evaluation
18(5)
3.1.3.1 Aisle temperature and humidity levels
18(1)
3.1.3.2 HVAC unit operation
18(1)
3.2 Equipment Installation Verification Tests
18(1)
3.3 Equipment Troubleshooting Tests
19(4)
CHAPTER 4 EQUIPMENT PLACEMENT AND AIRFLOW PATTERNS 23(8)
4.1 Equipment Airflow
23(2)
4.1.1 Airflow Protocol Syntax
23(1)
4.1.2 Airflow Protocol for Equipment
23(1)
4.1.3 Cabinet Design
24(1)
4.2 Equipment Room Airflow
25(6)
4.2.1 Placement of Cabinets and Rows of Cabinets
25(1)
4.2.2 Cabinets with Dissimilar Airflow Patterns
25(1)
4.2.3 Aisle Pitch
26(5)
CHAPTER 5 EQUIPMENT MANUFACTURERS HEAT AND AIRFLOW REPORTING 31(4)
5.1 Providing Heat Release and Airflow Values
31(1)
5.2 Equipment Thermal Report
32(3)
5.2.1 Example Thermal Report
34(1)
REFERENCES 35(2)
APPENDIX A PSYCHROMETRIC CHARTS 37(8)
APPENDIX B TEMPERATURE AND ALTITUDE CHARTS 45